Performance Index
① The accuracy class of the transmitter conforms to the Verification Regulation of the Pressure Transmitter (JJG 882-2004).
② The service temperature of connecting cable ranges from -20°C to 70°C.
③ No accumulation within one year.
Measuring range |
-0.1MPa…0MPa~0.005…100MPa 0kPa~200kPa…20MPa 0kPa~200kPa…20MPa |
||
Power supply |
4.5V~5.5V DC |
8V~28V DC |
8V~28V DC |
Output signal |
4~20mADC 0~10/20mADC 0~5V/10VDC 1~5VDC RS485 signal HART protocol
|
||
Working temperature |
-40°C~125°C |
-40°C~125°C |
-20°C~85°C |
Accuracy class |
1.0① |
||
Zero temperature error |
<±0.02%FS/°C (reference temperature: 25°C) |
||
Full scale temperature error |
<±0.02%FS/°C (reference temperature: 25°C) |
||
Storage temperature |
-40°C~125°C② |
||
Stability |
≤±0.5%FS③ |
||
Overpressure |
1.5×FS |
||
Relative humidity |
0%~90%. |
||
Vibration |
10g, 55Hz~2000Hz |
||
Impact |
100g, 11ms |
||
Insulation resistance |
>10 MΩ, 500 VDC |
||
IP rating |
IP65 |
||
Medium compatibility |
Al2O3 fluorinated silicone rubber, 1Cr18Ni9Ti stainless steel |
Electrical connection
Line color |
Two-wire system |
Three-wire system |
Black |
Power supply+ (+V) |
Power supply+ (+V) |
Red |
Power supply- (0V/+OUT) |
Common port (GND) |
Blue |
Neutral |
Output+ (+OUT) |
Outline Structure
(Unit: mm)
Selection Guide
YZB100 |
Pressure transmitter |
|||||
Code |
Outline structure |
|||||
B |
Packard plug-in type |
|||||
C |
Cable outgoing mode; length of cable: 1.5m |
|||||
Measuring range |
Measuring range: 0 kPa~200 kPa…20 MPa |
|||||
[0~X] kPa or MPa |
X --- measuring range |
|||||
Code |
Output signal |
|||||
E |
4mA~20mA DC |
|||||
F |
1V~5V DC |
|||||
K |
0.5V~4.5V DC |
|||||
Code |
Pressure interface |
|||||
C2 |
G 1/4 external thread connection |
|||||
C7 |
1/8NPT external thread connection |
|||||
C15 |
R1/4 external thread interface |
|||||
Code |
Additional function |
|||||
G |
Gauge pressure |
|||||
YZB100 B [0~1.6] MPa K C15 G complete model and specification |
Notes for Selection
1. Please be noted that the measured medium should be compatible with the part contacting with the product while the selection is made.
2. If straight thread is selected, the seal ring at the bottom of the interface thread shall be sealed without any Teflon tape required as auxiliary seal.
3. Please be noted that the insertion direction of plugs should be distinguished while the selection is made for connector type product.
4. The pressure interface of the transmitter can be customized according to users' requirements. Please indicate this in the contract.
5. For any special requirements on the performance parameters and functions of the product, please feel free to contact us.
http://www.youchurtsensor.com/